−850 mV CP Criterion

Criterion quick answer

A reading near or more negative than −850 mV relative to CSE is not automatically a pass.

First establish the applicable asset criterion, correct reference basis, authorized measurement route, required voltage-drop treatment, and measurement validity. Only then make the numerical comparison required by the applicable criterion.

Applies to

The controlling transformed authority establishes −850 mV CSE criterion routes for:

  • underground/submerged steel and gray/ductile cast-iron piping within SP0169-2024 scope;
  • steel underground storage-tank structures within SP0285-2021 scope;
  • on-grade carbon-steel tank bottoms within SP0193-2016 scope.

The similar number does not make the asset-specific requirements interchangeable.

Reference basis

The authorized −850 mV formulations use saturated CSE as the explicit reference basis. Do not compare a value on a different reference basis directly with −850 mV CSE unless the equivalent expression is defensibly controlled by applicable authority.

Measurement routes by asset

Asset scopeAuthorized route summarized by C2
Pipeline — SP0169-2024−850 mV or more negative relative to saturated CSE using a direct polarized-potential measurement, or a current-applied potential with required consideration of voltage drops in earth and metallic paths.
UST — SP0285-2021−850 mV CSE with CP applied and voltage-drop consideration, or −850 mV CSE polarized potential. For specified impressed-current and field-installed galvanic-anode UST systems, Instant-OFF is identified as the primary method for considering voltage drops, while other engineering methods are allowed.
On-grade carbon-steel tank bottom — SP0193-2016−850 mV CSE with CP current applied and voltage-drop consideration, or −850 mV CSE polarized potential. Measurement geometry and reference placement remain asset-specific.

What a defensible criterion decision requires

  1. Applicability: establish the governing asset scope and that this criterion route applies.
  2. Reference basis: establish the required CSE basis or a defensibly controlled equivalent.
  3. Measurement route: establish a defensible polarized potential or an allowed current-applied potential.
  4. Voltage-drop treatment: for a current-applied route, consider significant voltage drops as required.
  5. Measurement validity: establish adequate reference condition, placement, current state, timing, residual-current, meter/circuit, and other relevant controls.
  6. Numerical comparison: only now apply the exact comparison for the applicable asset authority.

What does not establish compliance

  • “The meter reads −850 mV.”
  • “The ON reading is −900 mV CSE.”
  • “The rectifier was turned off.”
  • “The OFF reading is more negative than −850 mV.”
  • “The structure met −850 mV last year.”
  • “The 100 mV criterion also looks close.”

Field cautions

  • A more negative number can still be a poor criterion measurement if the state or voltage-drop treatment is wrong.
  • A questionable Instant-OFF value is not rescued by being numerically beyond −850 mV.
  • Instant-OFF does not automatically remove all IR drop.
  • Meeting an applicable CP criterion does not establish that interference is acceptable.
  • This criterion is not interchangeable with the 100 mV Polarization Criterion.

Next action

Use Structure-to-Electrolyte Potential for measurement meaning, Reference Electrode and Reference-Electrode Placement for reference controls, Meter Loading for circuit-loading validity, Instant-OFF Potential for interrupted-value interpretation, IR Drop for voltage-drop effects, and 100 mV Polarization Criterion when evaluating demonstrated polarization change instead of this absolute-potential route.

Technical visuals

Criterion evaluation depends on asset, reference basis, measurement state, voltage-drop treatment, and applicability—not a single-number gauge.
Criterion evaluation depends on asset, reference basis, measurement state, voltage-drop treatment, and applicability—not a single-number gauge.